Mindray PM-50 Hand Held Pulse Oximeter


The Mindray PM-50 Hand-Held Pulse Oximeter is small & lightweight.
Mindray PM-50 measures blood oxygen saturation (%SpO2) and pulse rate.
Mindray PM-50 comes
with a THREE YEAR Manufacturer's Warranty!
LIST PRICE $399.00
SALE PRICE $245.00

To inquire about great savings on multiple unit orders call or click
HERE
to
contact us.
 
Mindray PM-50
Pulse Oximeter Highlights:
-
FDA
Approved for accuracy
-
Low
Cost of Ownership - replacement probes cost just $75!
-
Suitable for adult, pediatric and neonatal patients
-
Convenient size and weight for spot check monitoring (4.5 oz without
batteries & sensors)
-
Automatic Standby and Power-off
-
Convenient AA size alkaline or rechargeable batteries
-
Mindray PM-50 Pulse Oximeter comes with a 3 year Manufacturer's warranty
Mindray PM-50 Pulse Oximeter Includes:
-
Adult
Sensor
-
Users
Manual
Mindray PM-50 Documents:
Mindray PM-50 Brochure
Mindray PM-50 Technical Specifications
Mindray
PM-50 FDA Approval Letter (510K)
|
Mindray Pulse Oximeter Sensors |
|

MINDRAY 512F
• Adult reusable SpO2 Sensor
•
For patients over 45
lb.
•
6 Month Warranty
•
3 foot cable
•
Fits
Mindray PM-50, PM-60 only
LIST PRICE $105.00
SALE PRICE $75.00

|

MINDRAY 512E
• Adult
Soft Sensor
•
For patients over 45
lb.
•
6 Month Warranty
•
3 foot cable
•
Fits
Mindray PM-50, PM-60 only
LIST PRICE $115.00
SALE PRICE $85.00

|

MINDRAY 518B
• Adult/Pediatric/Neonatal
Band reusable SpO2 Sensor
•
3 foot cable
•
Patients 7 lbs. and up
•
6 Month Warranty
•
Fits
Mindray PM-50, PM-60 only
LIST PRICE $115.00
SALE PRICE $85.00

|
|

MINDRAY 512H
• Pediatric reusable SpO2 Sensor
•
3 foot cable
•
Patients 22 lbs. to 88 lbs.
•
6 Month Warranty
•
Fits
Mindray PM-50, PM-60 only
LIST PRICE $115.00
SALE PRICE $85.00

|
|
|
Technical Specifications
Mindray is
a trade mark of Shenzhen Mindray Bio-Medical Electronics Co. Ltd. Specification
subject to be changed without notice
Description
The PM-50
pulse oximeter is intended for noninvasive spot-check measurement of functional
oxygen saturation of arterial hemoglobin (SpO2).
Patient
Range
Adult, Pediatric and Neonatal
SpO2
Range 0-100%
Resolution 1%
Accuracy (70-100%)
+/-2% Adult
Method Dual wavelength LED
Heart
(Pulse) Rate
Range 25-254bpm
Resolution 1bpm
Accuracy 2bpm
Display
Type Backlit LCD
Parameters SpO2; PR
Status Standby; Communication; Download
Information Patient ID; Indicator of data storage;
Low power; Pleth. Bar;
Error; Standby
Mechanical
Weight
4.6oz without batteries and sensors
Size 65 x 140 x 32mm(WxHxD)
Battery
Type 4 AA Alkaline batteries or
4 AA rechargeable
batteries
Life Approximately 15 hours for normal
measurement status
Environmental
Operating Temperature 0 - 50c
Storage Temperature -20 - 60c
Operating Humidity 15%RH - 95%RH(noncondensing)
Storage Humidity 10%RH - 95%RH(noncondensing)
Classification
Type of Protection Internally powered equipment
Degree of Protection Before
(BF)
Safety IEC 60601-1, EN 865, ISO 14971
Storage
Patient ID Up to 100
Data records Up to 200
System
Output
Com Port RS-232
Auxiliary Software Record management and data
Printing through PC

Mindray is a leading medical device designer and
manufacturer in China and at the same time has won fame in the global market for
its initiative and world-class products. Since its establishment in 1991,
Mindray has been devoted itself to R&D and manufacture of medical devices
including patient monitors, clinical laboratory instruments and reagent, and
ultrasound imaging systems. Mindray's price-performance products are being
extended all over the world.
Mindray's headquarters are located in Shenzhen,
with 29 offices in major cities of China, as well as representative offices in
USA, Canada, UK, Turkey and Hong Kong. In addition, a solid distribution network
has been established around the world to market Mindray's products and serve
customers.
Mindray obtained ISO9001 Quality Assurance
certification in 1995. Most of its products are CE marked or FDA approved.
Safety and reliability make its products highly recognized and valued by clients
all over the globe.
Through cooperation with world-famous medical
equipment companies for more than 3 years, Mindray has obtained invaluable
experience in ODM business, especially in regulation, documentation and
communication aspects.
|
Home
|
Finger Oximeters
|
Hand Held Oximeters
|
General Information
|
|
Resources
|
Links |
|