|
Nonin
Sensors / Probes
|
Nonin
Reusable Articulated Spring Clip Sensors
  |
|

Nonin 8000AA
Adult
(>66 lbs) articulated internal spring finger sensor
3 foot cable
Fits Nonin 8500, 9840, 2500, 9600, 9700, 2120 series oximeters
LIST PRICE $165.00
SALE PRICE $160.00

|

Nonin 8000AA-WO
Adult
(>66 lbs) articulated internal spring finger sensor
1 foot cable
Fits
Nonin 3100
WristOx
series oximeter
LIST PRICE $165.00
SALE PRICE $160.00

|

Nonin 8000AP
Pediatric (22 to 88 lbs) articulated external spring
finger sensor,
3 foot cable
Fits Nonin 8500, 9840, 2500, 9600, 9700, 2120 series oximeters
LIST PRICE $165.00
SALE PRICE $160.00

|
|
Nonin
Wrap Sensors , Data & Extension Cables |
|

Nonin 8000J-WO
Adult
Flexiwrap finger sensor
Includes 25 Flexiwraps
3 foot cable
Fits
Nonin 3100
WristOx
series oximeter only
LIST PRICE $107.00
SALE PRICE $105.00

|

Nonin 8000J
Adult
Flexiwrap finger sensor
Includes 25 Flexiwraps
3 foot cable
Fits Nonin 8500, 9840, 2500, 9600, 9700, 2120 series oximeters
LIST PRICE $107.00
SALE PRICE $105.00

|

Nonin 1000MC
Serial
Cable for PC interface
Fits Nonin 8500, 9840, 2500, 9600, 9700, 2120 series oximeters
LIST PRICE $95.00
SALE PRICE $90.00

|
|

Nonin UNI-EXT-3
BACKORDERED
10
Foot Extension Cable
Fits Nonin 8500, 9840, 2500, 9600, 9700, 2120 series oximeters
LIST PRICE $85.00
SALE PRICE $84.00

|

Nonin 8001J
Neonate
Flexiwrap sensor
3 foot cable
Includes 25 Flexiwraps
Fits Nonin 8500, 9840, 2500, 9600, 9700, 2120 series oximeters
LIST PRICE $107.00
SALE PRICE $105.00

|

Nonin 1000SC-WO
Serial
Cable for PC interface with Nonin 3100
Fits
Nonin 3100 WristOx
series oximeter
LIST PRICE $95.00
SALE PRICE
$90.00

|
|
|
New!!
Nonin Reusable Soft Sensors |
|

Nonin
8000SL
Digit Thickness
.5 - 1.0 in
3 foot cable
Fits Nonin 8500, 9840, 2500, 9600, 9700, 2120 series oximeters
Comfortable fit for continuous monitoring
LIST PRICE $255.00
SALE PRICE $195.00

|

Nonin 8000SM
Digit Thickness
.4 - .75in
3 foot cable
Fits Nonin 8500, 9840, 2500, 9600, 9700, 2120 series oximeters
Comfortable fit for continuous monitoring
LIST PRICE $255.00
SALE PRICE $195.00

|

Nonin
8000SS
Digit Thickness
.3 - .5in
3 foot cable
Fits Nonin 8500, 9840, 2500, 9600, 9700, 2120 series oximeters
Comfortable fit for continuous monitoring
LIST PRICE $255.00
SALE PRICE $195.00

|
|
|
Nonin
Reusable Sensors - Ear Clip & Reflectance
|
|
|

Nonin
8000Q
Ear Clip Sensor
3 foot cable
Fits Nonin 8500, 9840, 2500, 9600, 9700, 2120 series oximeters
LIST PRICE $165.00
SALE PRICE $160.00

|

Nonin 8000R
Reflectance Sensor with 8000H Sensor Holder (10 caps
& 20 adhesive stickers),
3 foot cable
Fits Nonin 8500, 9840, 2500, 9600, 9700, 2120 series oximeters
LIST PRICE $165.00
SALE PRICE $160.00

|
|
|
|
Nonin PureLight sensors
produce a high-intensity pure light spectrum which eliminates variations in
readings from patient-to-patient and sensor-to-sensor.
The Nonin PureLight Principle:
Red and infrared light sources (LEDs)
are essential to pulse oximetry sensors.
- The red
LED measures
deoxygenated hemoglobin.
- The infrared
LED measures
oxygenated hemoglobin
Common red
LEDs may produce a
secondary spectrum emission (contamination)
- Contamination impacts the oxygenated hemoglobin measurement.
-
LED
contamination shifts the oximeterปs calibration curve resulting in
inaccurate SpO2 readings below 80%.
PureLight red
LEDs only produce
the pure light spectrum
- PureLight
LEDs do not
cause a shift in the oximeters calibration curve at SpO2 levels
below 80%.
- Nonin PureLight Sensors eliminate variations in readings from
patient-to-patient and sensor-to-sensor.
Accurate and dependable SpO2 readings start with PureLight
sensors.
|
Home
|
Finger Oximeters |
Hand Held Oximeters
|
General Information |
|
Resources
|
Links |
|